2D Symbologies
150
Magellan
TM
3200VSi
Aztec — continued
Length Control
Fixed Length Decoding—
When fixed length decoding is enabled, the scanner will decode a
bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding—
When variable length decoding is enabled, the scanner will
decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2
values.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming
Instructions below.
5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by
following the
Aztec Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Aztec Length 1, Length 2 Program-
ming Instructions below.
5. Set Length 2 to the maximum length by following the
Aztec Length 1, Length 2 Program-
ming Instructions
below.
START / END
PROGRAMMING bar codes
Variable Length Decoding
DEFAULT
Fixed Length Decoding