INSTALLATION
2
1 blinking/sec: a requested operation has been terminated
abnormally.
2 blinking/sec: a wrong operation has been requested (for
example the configuration in memory is not compatible
with the connected scanner).
STATUS (SL) (yellow) indicates the status of the non-volatile memory
support.
Off: the memory is empty (no configuration on board).
1 blinking/sec: the memory is not empty (a Get scanner
configuration service has been executed)*.
2 blinking/sec: the memory is not empty (a Get Scanner
Configuration service has been executed); however the
saved configuration is not compatible with the current
scanner one.
TRANSMISSION (TX) (green) indicates there is communication between the C-
BOX 150 and the scanner. This LED blinks during the
connection procedure.
* This is the typical state after correct system installation.