Symbologies
252 PowerScan
®
PD7100 Corded
Standard 2 of 5 — cont.
Standard 2 of 5 Minimum Reads
This feature specifies the minimum number of consecutive times a Standard 2 of 5 label
must be decoded before it is accepted as good read.
Standard 2 of 5 Decoding Level
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Minimum Reads = 1
Standard 2 of 5 Minimum Reads = 2
Standard 2 of 5 Minimum Reads = 3
Standard 2 of 5 Minimum Reads = 4
DEFAULT
NOTE
The Standard 2 of 5 Decoding Level feature is set using
2 of 5 Decoding
Level on page 196
.