Symbologies
258 PowerScan
®
PD7100 Corded
Standard 2 of 5 — cont.
Standard 2 of 5 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple
scans when decoding. Enabling correlation will help the scanner read labels that have
some spots and/or voids. It may also help read labels that have damaged areas. Enabling
correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Character Correlation = Disable
Standard 2 of 5 Character Correlation = Enable